Description

@TLucking

The accelerometer calibration routine (MPU6050_Base::PID()) uses a gravity constant that is exactly 2× too large. As a result, after running CalibrateAccel(), the sensor’s Z-axis reads ~2 g at rest (board flat) instead of ~1 g.

Fix:

  • if (ReadAddress == 0x3B) gravity = 32768 >> getFullScaleAccelRange();
  • if (ReadAddress == 0x3B) gravity = 32768 >> (getFullScaleAccelRange() + 1);
    // equivalent: gravity = 16384 >> getFullScaleAccelRange();

Explenation:
getFullScaleAccelRange() returns 0..3 for ±{2,4,8,16} g. The LSB-per-1 g sensitivity is 16384 >> fs. The code currently uses 32768 >> fs, which is 2 g. Shifting by +1 (i.e., dividing by 2) corrects the target from 2 g to 1 g across all ranges.