Add ubisys Dimmer D1 v2.7.1 (Stack 4.7.0) - #236
Open
zigpy-bot wants to merge 2 commits into
Open
Conversation
OTA File Submission File Information - Filename: 10F2-7B31-02710470_3517f4.ota - Original Filename: 10F2-7B31-0000-0006-02710470-spo-fmd.ota.zigbee - Manufacturer Directory: ubisys - Manufacturer ID: 0x10F2 (4338) - Image Type: 0x7B31 (31537) - File Version: 0x02710470 (40961136) - File Size: 153,598 bytes - Header String: ubisys D1 2.7.1 - File Min Hardware Version: 0x0000 (0) - File Max Hardware Version: 0x0006 (6) - Hosting: Repository file (hosted in zigpy-ota) - Existing Images Handling: Keep all existing images - Tested on Device: Yes Note: Existing Images Found The following existing image(s) with the same manufacturer ID and image type were found: - 10F2-7B31-02600460_099597.ota [stale] - Source File Name: 10F2-7B31-0000-0006-02600460-spo-fmd.ota.zigbee - File Version: 0x02600460 (39847008) (older than PR version) - File Size: 153,086 bytes Metadata - Source URL: https://www.ubisys.de/wp-content/uploads/10F2-7B31-0000-0006-02710470-spo-fmd.ota.zigbee Release Notes Changes: - On/Off and Level Control interaction: Refined the transient behaviour when an On, Off or Toggle command is received while a level transition is in progress, avoiding visually abrupt or unnatural output changes - Electrical Measurement and Metering clusters: Reworked both implementations for improved accuracy and specification conformance - Attribute scaling: Added support for multiplier and divisor attributes in the Electrical Measurement cluster, allowing reported values to be scaled to the applicable engineering units - Attribute reporting: Attribute reports now account for the case in which the current value of a reportable attribute is invalid or unavailable at the time the report is generated - Other bug fixes and improvements Full change log can be found here: https://www.ubisys.de/unterstuetzung/support-firmware/aenderungsprotokoll-d1/ Closes: #235 Co-authored-by: cmaschke <112077292+cmaschke@users.noreply.github.com>
4 tasks
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
OTA File Submission
File Information
10F2-7B31-02710470_3517f4.ota10F2-7B31-0000-0006-02710470-spo-fmd.ota.zigbeeubisys0x10F2(4338)0x7B31(31537)0x02710470(40961136)ubisys D1 2.7.10x0000(0)0x0006(6)Note: Existing Images Found
The following existing image(s) with the same manufacturer ID and image type were found:
10F2-7B31-02600460_099597.ota[stale]10F2-7B31-0000-0006-02600460-spo-fmd.ota.zigbee0x02600460(39847008) (older than PR version)Metadata
Release Notes
Changes:
Full change log can be found here:
https://www.ubisys.de/unterstuetzung/support-firmware/aenderungsprotokoll-d1/